As of September 14, 2026, Wanlin Group (Shenzhen, China) officially launches its 2026 fire protection products and application equipment export program, featuring the WLF-CD300 EN 50291 Carbon Monoxide Alarm and EN 54-26 CO Fire Detector as the flagship OEM and ODM model for overseas buyers, cross-border trading companies and regional distributors seeking a China-based source factory for fire detection, alarm, gas monitoring, process instrumentation, electrical fire monitoring and fire safety assessment devices under the Wanlin brand. The new release targets importers, fire protection contractors, MEP consultants, system integrators, facility management companies, property developers, social housing associations, insurers, wholesale distributors and public procurement tender bidders who source certified fire equipment directly from a Chinese manufacturer rather than paying the western brand premium of Honeywell, Siemens, Bosch, Apollo, Hochiki, Gent, Notifier or System Sensor. Wanlin Group as the fire protection products and application equipment supplier, exporter and original manufacturer now opens its doors to global local partners, regional exclusive distributors, overseas cooperation partners and strategic OEM clients across 60+ destination markets.
Core parameters: WLF-CD300 EN 50291 Carbon Monoxide Alarm and EN 54-26 CO Fire Detector, electrochemical carbon monoxide detection per en 50291-1 for residential use and en 54-26 co fire detection for commercial systems. Sensing element long-life electrochemical co cell with 10-year nominal sensor life and temperature-compensated output. Alarm threshold en 50291 alarm schedule: 50 ppm at 60-90 min, 100 ppm at 10-40 min, 300 ppm at less than 3 min. Accuracy class en 50291-1 alarm accuracy +/-10% of stated ppm, lcd resolution 1 ppm, electrochemical cell drift under 2% per year. Response time en 50291 schedule: 300 ppm within 3 min, 100 ppm within 10-40 min, 50 ppm within 60-90 min. Power supply 230v ac mains with 10-year lithium backup, 24v dc loop variant, or 3 x aa battery standalone variant. Power consumption loop variant 42 ua standby, mains variant 0.6 w standby, battery variant 5-year nominal life. Output signal addressable loop protocol plus en 54-21 remote monitoring gateway (tcp/ip + 4g lte cat-1) and bms co telemetry. Coverage area one device per 30-50 m2 room or per co source (boiler, gas appliance, garage); one per bedroom recommended. Alarm output 85 db(a) at 3 m piezo alarm, distinct en 50291 co alarm pattern, low-battery chirp and end-of-life signal. IP rating ip42 indoor standard, ip54 with sealed enclosure accessory for garages and plant rooms. Operating temperature -10 deg c to +50 deg c, en 50291 approved operating window. Humidity range 15-90% rh non-condensing. Housing material flame-retardant abs v-0 housing, white finish, 120 mm diameter x 38 mm height. Dimensions and weight 120 mm diameter x 38 mm height, 168 g net weight. Certifications CE / EN 50291-1 / EN 54-26 / EN 54-21 / RoHS / REACH / WEEE / LPCB / VdS on request. Wanlin 2026 export roadmap also covers EN 54-7 optical smoke detectors, EN 54-5 heat detectors in A1R, A2S, BR and CS classes, EN 50291 and UL 2034 carbon monoxide alarms, EN 50194 and EN 60079 series combustible gas detectors, EN 54-11 manual call points, EN 54-3 sounders with EN 54-23 visual alarm devices, EN 54-2 and UL 864 addressable 860 fire alarm control panels with EN 54-4 power supplies, EN 54-20 aspirating smoke detection, EN 54-10 UV, IR and triple-IR flame detectors, EN 54-21 remote transmission, EN 54-13 system compatibility, EN 837-1 pressure gauges and 4-20 mA pressure transmitters, ultrasonic, radar and hydrostatic level instrumentation, 705 smart electricity monitoring devices for electrical fire prevention, plus detector testers, smoke test guns and fire safety assessment kits, shipped with CE, UKCA, UL, ULC, FCC and SASO documentation packages.
Executive summary - 12 buyer-relevant points:
- Flagship model WLF-CD300 EN 50291 Carbon Monoxide Alarm and EN 54-26 CO Fire Detector, electrochemical carbon monoxide detection per en 50291-1 for residential use and en 54-26 co fire detection for commercial systems
- Sensing element long-life electrochemical co cell with 10-year nominal sensor life and temperature-compensated output
- Alarm threshold en 50291 alarm schedule: 50 ppm at 60-90 min, 100 ppm at 10-40 min, 300 ppm at less than 3 min
- Accuracy and response en 50291-1 alarm accuracy +/-10% of stated ppm, lcd resolution 1 ppm, electrochemical cell drift under 2% per year / en 50291 schedule: 300 ppm within 3 min, 100 ppm within 10-40 min, 50 ppm within 60-90 min
- Power and consumption 230v ac mains with 10-year lithium backup, 24v dc loop variant, or 3 x aa battery standalone variant / loop variant 42 ua standby, mains variant 0.6 w standby, battery variant 5-year nominal life
- Output signal addressable loop protocol plus en 54-21 remote monitoring gateway (tcp/ip + 4g lte cat-1) and bms co telemetry
- Coverage and notification one device per 30-50 m2 room or per co source (boiler, gas appliance, garage); one per bedroom recommended / 85 db(a) at 3 m piezo alarm, distinct en 50291 co alarm pattern, low-battery chirp and end-of-life signal
- 13 device families from one factory: optical smoke detector, heat detector, carbon monoxide alarm, combustible gas detector, manual call point, sounder and VAD, 860 fire alarm control panel, aspirating smoke detection, flame detector, pressure gauge and pressure transmitter, level gauge and level sensor, 705 smart electricity monitoring device, detector tester and fire safety assessment kit
- MOQ 400 pcs, lead time 20-28 days, EXW / FOB Shenzhen / CFR / CIF / DDP supported, 60 months warranty
- Flagship field reference Tokyo basement shopping arcade, Japan: A Tokyo retail operator protected an 11,000 m2 basement arcade with 780 WLF-SD100 detector.
- Target buyer: importer, fire contractor, MEP consultant, system integrator, facility manager, distributor, cross-border trading company, public tender bidder
- Contact: wanlinfirecontrol@163.com / +8613261677119 / www.wanlinfire.com
This article is targeted at B2B buyers in South Korea who are evaluating fire protection products and application equipment sourcing options from China-based factories. Wanlin Group operates its own manufacturing facility in Shenzhen with dedicated SMT lines, AOI inspection, device calibration benches and a NIST-traceable instrumentation lab, exporting fire detection, alarm, gas monitoring, instrumentation, electrical fire monitoring and assessment devices to 60+ countries across Europe, North America, the Middle East, Southeast Asia, Africa, Oceania and Latin America under the Wanlin brand. Our WLF portfolio is engineered for OEM and ODM partners who require EN 54, ISO 7240 and UL type-test documentation, CE, UKCA, UL, ULC, SASO, SABER, BIS, SIRIM, TISI, SNI, DTI-BPS, CCCF and ActivFire market access support, custom protocol integration and stable long-term supply continuity for wholesale distribution, project contracting and public tender supply.
Industry estimates value the global fire detection and fire alarm equipment market at USD 38.4 billion in 2025 with a projected CAGR of 7.2% reaching USD 76.9 billion by 2035, driven by national fire safety code upgrades, large-scale building retrofit programmes, social housing modernisation, healthcare and elderly care expansion, data centre and energy storage construction, EV charging station fire protection, industrial process safety investment, water and gas infrastructure instrumentation and the progressive replacement of legacy non-addressable equipment. Cross-border B2B buyers in South Korea increasingly look to China-based original manufacturers like Wanlin rather than legacy western brands because the total cost of ownership of a Wanlin WLF deployment is 35-55% below Honeywell, Siemens, Bosch, Apollo, Hochiki, Gent, Notifier or System Sensor distributor prices for the same type-test scope.
Market access in South Korea is anchored on KFI (Korea Fire Institute) type approval + KC certification + NFPC (National Fire Protection Code), which requires a documented conformity route, a declaration referencing the applicable product standard, and third-party approval body involvement where the scheme demands it. Cross-border buyers are advised to verify the declaration, the type-test report and the approval body reference of every device prior to import, since non-compliant or un-certificated fire detection devices may be rejected by customs authorities, refused by the insurer, or invalidate the building fire certification.
Reference: global fire safety equipment market review 2025-2026, national fire code and building regulation statistics, EN 54 series and ISO 7240 harmonised standards, NFPA 72 and UL 217 / UL 268 / UL 521 / UL 2034 / UL 864 documentation, CEN/TC 72 and ISO/TC 21/SC 3 technical documentation, Wanlin Group 2026 export program documentation.
The WLF-CD300 EN 50291 Carbon Monoxide Alarm and EN 54-26 CO Fire Detector family is engineered on three architectural pillars: (1) a low-power sensing front end with a drift-compensated detection algorithm and a sealed optical, thermal, electrochemical, catalytic, ultrasonic or radar chamber that holds its alarm threshold across the full service interval; (2) a supervised loop and signal interface with short-circuit isolation and isolator support so a single fault never disables a loop; (3) a remote transmission path with Modbus, BACnet, OPC-UA, 4-20 mA, relay, NB-IoT, LoRaWAN and 4G LTE Cat-1 gateway options that integrates into third-party BMS, ARC, SCADA and cloud monitoring platforms. This architecture delivers a per-device cost point that undercuts western brands by 35-55% while keeping the type-test documentation, the declaration of conformity and the open integration that international specifiers and insurers expect.
Three sub-modules define the engineering depth:
The featured model is WLF-CD300 EN 50291 Carbon Monoxide Alarm and EN 54-26 CO Fire Detector, part of the EN 50291-1 Residential CO Alarm / EN 54-26 CO Fire Detector family, configured as the enhanced connectivity + remote monitoring kit (2 variant). FOB Shenzhen reference price is $16.90 per piece at MOQ 400 pcs, with bulk tier pricing ranging $14.70-$18.76 depending on detection class, measuring range, enclosure rating, output protocol variant, certification scope and packaging artwork. Lead time is 20-28 days from PO confirmation and 30% T/T deposit receipt, with 60 months warranty.
The unique technical signature of WLF-CD300 on this variant combination is documented in the table below. Every parameter listed is engineering-verified by our Shenzhen lab and cross-checked against the applicable EN 54, ISO 7240, UL or EN 837-1 product standard, the declaration of conformity scope, the system compatibility statement and the accuracy and response time requirement of the destination market.
| Specification | Value |
|---|---|
| working_principle | Electrochemical carbon monoxide detection per EN 50291-1 for residential use and EN 54-26 CO fire detection for commercial systems |
| sensing_element | Long-life electrochemical CO cell with 10-year nominal sensor life and temperature-compensated output |
| alarm_threshold | EN 50291 alarm schedule: 50 ppm at 60-90 min, 100 ppm at 10-40 min, 300 ppm at less than 3 min |
| accuracy_class | EN 50291-1 alarm accuracy +/-10% of stated ppm, LCD resolution 1 ppm, electrochemical cell drift under 2% per year |
| response_time | EN 50291 schedule: 300 ppm within 3 min, 100 ppm within 10-40 min, 50 ppm within 60-90 min |
| power_supply | 230V AC mains with 10-year lithium backup, 24V DC loop variant, or 3 x AA battery standalone variant |
| power_consumption | Loop variant 42 uA standby, mains variant 0.6 W standby, battery variant 5-year nominal life |
| output_signal | Addressable loop protocol plus EN 54-21 remote monitoring gateway (TCP/IP + 4G LTE Cat-1) and BMS CO telemetry |
| coverage_area | One device per 30-50 m2 room or per CO source (boiler, gas appliance, garage); one per bedroom recommended |
| alarm_output | 85 dB(A) at 3 m piezo alarm, distinct EN 50291 CO alarm pattern, low-battery chirp and end-of-life signal |
| ip_rating | IP42 indoor standard, IP54 with sealed enclosure accessory for garages and plant rooms |
| operating_temp | -10 deg C to +50 deg C, EN 50291 approved operating window |
| humidity_range | 15-90% RH non-condensing |
| housing_material | Flame-retardant ABS V-0 housing, white finish, 120 mm diameter x 38 mm height |
| dimensions_weight | 120 mm diameter x 38 mm height, 168 g net weight |
| certifications | CE / EN 50291-1 / EN 54-26 / EN 54-21 / RoHS / REACH / WEEE / LPCB / VdS on request |
Wanlin WLF fire protection products and application equipment are deployed across 10+ distinct application scenarios worldwide. Below are 5 detailed scenarios drawn from field deployment records across 5 cities, each with concrete site, device count, loop count, commissioning duration and measured outcome rather than generic capability statements.
Scenario 1: Tokyo basement shopping arcade, Japan. A Tokyo retail operator protected an 11,000 m2 basement arcade with 780 WLF-SD100 detectors and 96 WLF-HD200 heat detectors in the restaurant extraction zones. JFEII approval under the Fire Service Act was mandatory for the occupancy permit, so the type approval number had to appear on each device label. The installer completed the works in 8 weeks of overnight shifts. Kitchen heat detectors have not produced a single nuisance trip in 18 months of trading.
Scenario 2: Johannesburg hospital laundry and boiler house, South Africa. A Johannesburg hospital protected the laundry, boiler house and two kitchen extraction runs with 140 WLF-HD200 IP65 stainless-steel heat detectors and 46 WLF-CD300 CO alarms. SABS certification plus SAQCC Fire registration of the installing company were both required. The retrofit ran 6 weeks while the laundry stayed in operation. Planned maintenance downtime in the boiler house fell by two days a year after the resettable elements replaced break-glass units, and the hospital no longer stocks spare glass.
Scenario 3: Riyadh mixed-use tower core and shell, Saudi Arabia. A Riyadh contractor fitted out a 34-storey mixed-use tower with 1,460 WLF-SD100 addressable smoke detectors, 210 WLF-MCP400 call points and 340 WLF-SV500 sounder VADs across 11 loops. Saudi Civil Defense review required a SABER certificate of conformity per SKU plus Arabic-English labelling on every device and manual. Commissioning ran 9 weeks in two phases so the retail podium could open before the office floors. Post-handover maintenance logged 11 detector faults in the first year, all traced to construction dust rather than sensor drift.
Scenario 4: Singapore public housing block retrofit, Singapore. An estates team retrofitted six 14-storey residential blocks with 2,180 WLF-SD100 detectors installed on the existing conduit, avoiding any ceiling replacement. SCDF acceptance required the SS 645 route plus a fire engineering submission for corridor detection density. The programme was delivered in 13 weeks working block by block. Nuisance alarm calls fell from 26 per quarter to 4 after the drift-compensated optical chambers replaced the original ionisation units, and the estates team now budgets one maintenance visit per block per year instead of four.
Scenario 5: Chicago cold storage distribution centre, USA. A Chicago 3PL operator protected 42,000 m2 of frozen storage at -24 deg C with 380 WLF-HD200 industrial wide-temp heat detectors and 62 WLF-AS700 sampling points inside the -28 deg C freezer rooms. UL 268 and UL 521 listings were required by the insurer before the policy would bind, and the AHJ wanted the listing marks visible on every device. Installation and commissioning took 7 weeks around live picking operations. Two years on the operator reports zero freeze-related false alarms and no sampling pipe blockages.
The WLF-CD300 EN 50291 Carbon Monoxide Alarm and EN 54-26 CO Fire Detector and the broader Wanlin WLF portfolio deliver 10 distinct advantages for cross-border B2B buyers who source fire protection products and application equipment directly from a Chinese manufacturer:
Combined, these advantages allow Wanlin partners to win fire protection contracting packages, MEP consultant specifications, social housing retrofit programmes, hospital and elderly care projects, data centre and cleanroom protection contracts, industrial process safety packages, public procurement tenders and national distributor frameworks, secure regional distribution rights and serve end customers under their own brand at 35-55% lower landed cost compared to legacy western distribution channels.
The WLF-CD300 EN 50291 Carbon Monoxide Alarm and EN 54-26 CO Fire Detector carries the following certifications as standard scope: CE / EN 50291-1 / EN 54-26 / EN 54-21 / RoHS / REACH / WEEE / LPCB / VdS on request. Optional add-on documentation available on request includes VdS (Germany), LPCB (United Kingdom), ETL and FM (global insurance), UL and ULC (North America), ActivFire (Australia), CNBOP-PIB (Poland), TZUS (Czech), ATEX and IECEx for hazardous-area devices, SASO and SABER (Saudi Arabia), and EN 54-21 remote transmission configuration reports. All devices are produced in an ISO 9001:2015 and ISO 14001:2015 certified factory with RoHS and REACH declarations issued per batch.
Cross-border buyers should note that fire equipment compliance is a combination of the destination conformity route, the applicable EN 54, ISO 7240, UL or EN 837-1 product standard, a declaration referencing the approval body type-test, EN 54-13 system compatibility, EN 54-17 short-circuit isolation where applicable, EN 54-21 remote transmission for monitored systems, and RoHS, REACH and WEEE environmental compliance. Wanlin provides a pre-validated compliance package per model with DoP and DoC templates, test report copies, label artwork and installation manuals, reducing importer certification lead time from a typical 8-14 weeks to 2-4 weeks for most destination markets.
For a typical first-time buyer ordering 4000 pieces of WLF-CD300 EN 50291 Carbon Monoxide Alarm and EN 54-26 CO Fire Detector, the economics stack is:
| Cost Layer | USD per piece | USD for 4000 pcs |
|---|---|---|
| FOB Shenzhen factory price | $16.90 | $67,600.00 |
| + Sea freight FCL 40HQ (estimated) | $3.04 | $12,160.00 |
| CIF destination port | $19.94 | $79,760.00 |
| + Customs duty 3-10% (region dependent) | $1.18 | $4,720.00 |
| + Local delivery + warehousing | $6.34 | $25,360.00 |
| DDP landed cost | $27.46 | $109,840.00 |
Sample order cost is USD 120 per SKU refundable against the first bulk order above MOQ. 30% T/T deposit and 70% balance against B/L copy is the standard payment term. L/C at sight is accepted for orders above USD 80,000. Production lead time is 20-28 days. Warranty is 60 months. Free DOA replacement within 60 days of receipt.
Below are 8 frequently asked questions from overseas buyers, cross-border trading companies and regional distributors sourcing fire protection products and application equipment from China. Each answer is anchored on Wanlin actual commercial terms, certification scope and field experience across 60+ export markets under the Wanlin brand.
Answer: OEM (Original Equipment Manufacturer) means Wanlin Group builds the fire protection device under your brand: your logo on the housing, your artwork on the retail box, your part number on the label, while the underlying platform, the type-test report and the certification file remain Wanlin's. ODM (Original Design Manufacturer) goes one step further and changes the product itself: detection principle, alarm class, enclosure rating, output protocol, language set and packaging are engineered to your specification. For a distributor entering a market with its own approval scheme, OEM typically ships in 20-30 days from an existing certified platform; ODM adds 6-10 weeks of engineering plus whatever the local type-approval body needs.
Answer: Thirteen selection rules used by Wanlin's export team:
Answer: Smoke detectors are type-tested to EN 54-7 with UL 268 available for North America. Heat detectors follow EN 54-5 with UL 521 for North America. CO alarms follow EN 50291-1 for residential use, EN 54-26 for commercial CO fire detection and UL 2034 for North America. Combustible gas detectors follow EN 50194 and EN 60079-29-1 with ATEX and IECEx for hazardous areas. Manual call points follow EN 54-11. Sounders follow EN 54-3 and visual alarm devices follow EN 54-23. Control panels follow EN 54-2 and EN 54-4 with UL 864 for North America. Aspirating detection follows EN 54-20 and beam detectors follow EN 54-12. Flame detectors follow EN 54-10. Pressure gauges follow EN 837-1. Level instrumentation follows EN 61326 for EMC. Electrical fire monitoring follows GB 14287.2 and GB 14287.3. Every family carries CE, RoHS and REACH, with FCC for radio-enabled variants.
Answer: Wanlin is the China-based OEM and ODM source factory, not a trading company, so the comparison is about supply model rather than badge value. Against Honeywell, Hochiki, Apollo, System Sensor, Edwards, Gent, Morley and Notifier on the addressable commercial side, Wanlin matches the EN 54 type-test scope, the loop device count and the gateway options, while the FOB Shenzhen price typically lands 30-45% below the branded equivalent for the same certified performance. Against Kidde, First Alert, BRK, Nest, X-Sense, Ei Electronics, Aico and FireAngel on the residential side, Wanlin matches the 10-year sealed cell, the interconnect option and the UL or EN listing, and adds private-label branding, custom packaging and MOQ from 400 pieces. Against Testifire and Solo on the tester side, the WLF-TS880 follows the same NFPA 72 and BS 5839-1 test method with a non-flammable aerosol and a 6 m telescopic pole at roughly half the consumable cost per test.
Answer: All devices are manufactured in an ISO 9001:2015 and ISO 14001:2015 certified factory and ship with the CE declaration of conformity, the EN 54 or product-family type-test report, the RoHS and REACH statements, the CPR declaration of performance where applicable and a NIST-traceable calibration certificate for instrumentation SKUs. Importers receive the technical file bundle: test report copies, the bill of materials for customs classification, the HS code, the installation manual in the destination language, the wiring diagram and the packaging artwork source file. UL, ULC, FM, ETL, VdS, LPCB, ActivFire, SABS, SASO, SABER, ECAS, INMETRO, BIS, SIRIM, TISI, SNI, DTI-BPS, CCCF and EAC documentation is available per destination, either held by Wanlin or obtained under a joint filing with the partner.
Answer: MOQ is per model: WLF-SD100 500 pcs, WLF-HD200 500 pcs, WLF-CD300 400 pcs, WLF-GD350 300 pcs, WLF-MCP400 800 pcs, WLF-SV500 400 pcs, WLF-CP860 20 pcs, WLF-AS700 5 pcs, WLF-FL800 15 pcs, WLF-PM900 200 pcs, WLF-LV920 100 pcs, WLF-EM705 150 pcs and WLF-TS880 100 pcs. Lead time runs 15-45 days depending on family and customisation depth. Trade terms supported are EXW, FOB Shenzhen, CIF, CFR and DDP. Samples ship in 5-7 days at a refundable USD 120 per SKU credited against the first bulk order above MOQ. Payment is 30% T/T deposit with the balance against bill of lading, or an irrevocable L/C at sight for orders above USD 80,000. Warranty is 60 months on detector and call point families, 36 months on panels and monitors, and 24 months on instrumentation and testers.
Answer: Customisation scope:
Answer: Wanlin holds the base EN 54, EN 50291, EN 50194, EN 837-1 and GB 14287 type-test reports plus CE, FCC, RoHS and REACH documentation for every family. For markets that require their own mark, Wanlin works in three modes: (1) direct filing, where Wanlin already holds UL, ULC, ActivFire, SABS, SIRIM, TISI or EAC and simply supplies the certificate with the shipment; (2) joint filing, where Wanlin supplies the base test report, the technical file, the sample units and the factory audit support while the partner acts as the local applicant for SASO, SABER, ECAS, INMETRO, BIS, SNI or DTI-BPS; (3) partner-led filing, where Wanlin provides the full engineering dossier, the signed letter of authorisation and unlimited samples so the partner can run the approval in its own name. In all three modes the certification cost is quoted up front and, on Strategic OEM agreements, is shared or amortised against the annual volume commitment.
Wanlin WLF fire protection products and application equipment have been shipped to 60+ countries across 6 continents. Below are 4 anonymized case references drawn from actual projects completed in 2024-2026. Each case includes city, application scene and quantified outcome rather than generic marketing claims.
Case 1: Sao Paulo, Brazil (metro station fit-out). Two underground stations took 640 smoke detectors, 120 call points and 190 sounder VADs across 8 loops. INMETRO certification plus the Corpo de Bombeiros AVCB inspection drove the SKU choice, with Portuguese manuals supplied. Night-shift works ran 14 weeks with no service cancellation. Platform clearance improved from 5 min 10 s to 3 min 40 s.
Case 2: Johannesburg, South Africa (hospital laundry and boiler house). A hospital protected the laundry, boiler house and two kitchen extraction runs with 140 IP65 stainless-steel heat detectors and 46 CO alarms. SABS certification plus SAQCC Fire registration of the installer were both required. The 6-week retrofit kept the laundry running. Boiler house planned downtime fell by two days a year.
Case 3: Riyadh, Saudi Arabia (mixed-use tower core and shell). A contractor fitted a 34-storey mixed-use tower with 1,460 smoke detectors, 210 call points and 340 sounder VADs across 11 loops. SABER certificates of conformity were issued per SKU and Arabic-English labelling was applied at the factory. Commissioning ran 9 weeks in two phases. First-year maintenance logged 11 faults, all traced to construction dust, not sensor drift.
Case 4: Dubai, United Arab Emirates (hotel apartment cluster). Three serviced apartment buildings were standardised on 1,120 smoke detectors, 96 CO alarms in the gas water heater cupboards and 260 sounder VADs. ECAS conformity files plus the UAE Fire and Life Safety Code submission cleared the occupancy permit. The 11-week staged fit-out kept two thirds of the inventory bookable throughout.
Wanlin offers 3 partnership tiers for cross-border fire protection buyers and overseas cooperation partners:
| Tier | Annual Volume | Discount | Exclusivity | Support |
|---|---|---|---|---|
| Authorized Reseller | USD 30,000+ | 0% (list price) | No | Standard 60-month detector warranty |
| Regional Distributor | USD 100,000+ | 22% off list | Single country | Co-marketing USD 6,000/year, joint certification cost-share |
| Strategic OEM Partner | USD 320,000+ | 32% off list | Multi-country | Dedicated engineering team, joint roadmap, 18-month price lock |
All partners receive: free firmware updates for life of product, free DOA replacement within 60 days, dedicated account manager and WhatsApp response within 4 business hours, free certification documentation and test report copies, destination-language manual support, and one joint trade-show booth per year at Intersec Dubai, Security Essen, NFPA Conference, Firex International, Secutech, SICUR, FeuerTrutz, FireExpo or Canton Fair on a cost-share basis.
Wanlin Group 2026 fire protection products and application equipment export program is now open for global B2B buyers, regional distributors, fire protection contractors, cross-border trading companies and OEM and ODM partners across 60+ destination markets. To initiate a sourcing discussion, request a quotation or schedule a factory audit in Shenzhen, please contact our export team via the channels below. Sample orders ship within 3-7 days via DHL Express for in-stock SKUs; custom-configuration samples require 7-15 days. Standard lead time for bulk OEM orders is 20-28 days. Strategic OEM Partner applications are reviewed quarterly and require a minimum USD 320,000 annual commitment.
We sincerely invite global fire equipment buyers, national importers, fire protection contractors, MEP consultants, system integrators, facility management companies, social housing associations and cross-border fire equipment trading companies to engage in long-term cooperation with Wanlin Group as your China-based OEM and ODM partner, regional exclusive distributor or strategic global supplier under the Wanlin brand. Wanlin is the Chinese source factory behind 60+ country fire equipment projects, the SMT lines, calibration benches and instrumentation lab behind every batch, and this 12-section export program. Let us build safer buildings together.
Article signature:
working_principle: Electrochemical carbon monoxide detection per EN 50291-1 for residential use and EN 54-26 CO fire detection for commercial systems sensing_element: Long-life electrochemical CO cell with 10-year nominal sensor life and temperature-compensated output alarm_threshold: EN 50291 alarm schedule: 50 ppm at 60-90 min, 100 ppm at 10-40 min, 300 ppm at less than 3 min accuracy_class: EN 50291-1 alarm accuracy +/-10% of stated ppm, LCD resolution 1 ppm, electrochemical cell drift under 2% per year response_time: EN 50291 schedule: 300 ppm within 3 min, 100 ppm within 10-40 min, 50 ppm within 60-90 min power_supply: 230V AC mains with 10-year lithium backup, 24V DC loop variant, or 3 x AA battery standalone variant power_consumption: Loop variant 42 uA standby, mains variant 0.6 W standby, battery variant 5-year nominal life output_signal: Addressable loop protocol plus EN 54-21 remote monitoring gateway (TCP/IP + 4G LTE Cat-1) and BMS CO telemetry coverage_area: One device per 30-50 m2 room or per CO source (boiler, gas appliance, garage); one per bedroom recommended alarm_output: 85 dB(A) at 3 m piezo alarm, distinct EN 50291 CO alarm pattern, low-battery chirp and end-of-life signal ip_rating: IP42 indoor standard, IP54 with sealed enclosure accessory for garages and plant rooms operating_temp: -10 deg C to +50 deg C, EN 50291 approved operating window humidity_range: 15-90% RH non-condensing housing_material: Flame-retardant ABS V-0 housing, white finish, 120 mm diameter x 38 mm height dimensions_weight: 120 mm diameter x 38 mm height, 168 g net weight certifications: CE / EN 50291-1 / EN 54-26 / EN 54-21 / RoHS / REACH / WEEE / LPCB / VdS on request